Typical
Site
Requirements
- Area
will be Bitumen sealed and graded (less than 3% fall to a central sump).
- Site
will be fully external bunded with truck access over drain or hump.
- Complete
worm bed area to be covered in a shed like structure, totally secure
from the elements.
- Vermitech
galvanised steel raised cage worm beds set in rows and tiers. A typical
bed is 60-100m long x 3.8m wide.
- Vermitech
will install a computer controlled watering system.
- Vermitech
will construct Vermicast storage shed and other site sheds for office,
plant storage and amenities.
- Ideally
the Site should be in close proximity to the source of the waste, and
will be constructed on the Clients land (set inside or adjacent to the
source of waste). A lease arrangement for the land can be entered into.
- Access
to the public road network.
- Access
to established electricity lines, water supplies and telephony services.
- Access
to reticulated waste water as this can be used in the place of freshwater
if the quality is adequate (pathogen free, silt levels, salt levels).
Pre-Design Requirements
- Vermitech
requires the provision of an acceptable geo-technical report proving
that the site is suitable to support a pavement and large metal
shed structure and has no ground water that would require the
installation of subsoil drainage.
- Further,
Vermitech requires provision of an acceptable survey of the site
to a scale not smaller than 1:500 showing contours (minimum 0.25m
contours) and cross sections at minimum intervals of 20m.
- Vermitech
requires the site to have an established man-proof fence enclosing
the site on its perimeter with lockable access gates.
|

Click
to view image full size
The
land requirements of each Site will vary according to the size of
the System installed, though each will be customized to suit the
area available
|
-
Fence should be sufficient to ensure that the site is secure, inaccessible
to the public and that Vermitechıs trade secrets in the Vermiculture
process are protected. Vermitech can make allowances to build such a
fence in its construction budget if none currently exists.
- Vermitech
can make allowances to build such a fence in its construction budget
if none currently exists. Vermitech
requires electricity supply and two main switchboards to two locations
on the site.
- Vermitech
requires portable water supply via a 50mm water line with domestic pressure
of 500Kpa to 700Kpa.
-
Vermitech however will supply fire extinguishers.
- Client
will also meet all fees required by relevant authorities for the construction
of the facility.
- Vermitech
also requires a wash down facility for cleaning and maintenance of biosolid
bins, trucks, tractors and other equipment.
|